Description: Two simple arrangements for resistive loads are shown in A and B. The circuit in A will provide load power when the actuating contact is closed, and no power when the contact is open. B provides the reverse of this action, supplying power to the load when the contact is open and no load power when the contact is closed. If desired, both circuits can be made to latch by operating with DC instead of the indicated AC supply. In both of these circuits, the voltage across the sensitive contacts is under 5 volts, and the contact current is below 5 mA. For inductive loads, Rl would normally be returned to the opposite side of the load as shown in C.
The described circuits A and B demonstrate fundamental configurations for controlling resistive loads through the manipulation of contact states. In circuit A, the load is energized only when the actuating contact is closed, effectively creating a straightforward on/off control mechanism. Conversely, circuit B operates in a manner that energizes the load when the contact is open, providing a unique control behavior that may be useful in specific applications where reverse activation is required.
Both circuits can be adapted for latching functionality by utilizing a DC power supply instead of the specified AC supply. This modification allows the circuits to maintain their state (either on or off) even after the actuating contact is released, which can be advantageous in applications requiring persistent load activation without continuous input.
The operational parameters of these circuits are designed for low-power applications, with the voltage across the sensitive contacts maintained below 5 volts and the contact current limited to under 5 mA. This design consideration ensures compatibility with delicate components and enhances the longevity and reliability of the circuit.
For applications involving inductive loads, it is recommended that the resistor Rl be connected to the opposite side of the load, as illustrated in circuit C. This configuration helps to manage the back EMF generated by inductive loads, protecting the circuit components from potential damage and ensuring stable operation. The careful arrangement of these components allows for effective control of both resistive and inductive loads, accommodating various operational requirements in electronic designs.Two simple arrangementsfor resistive loads are shown in A & B. The circuit in A will provide load power when the actuating contact is closed, and no power when the contact is open. B provides the reverse of this action-power being supplied to the load when the contact is open with no load power when the contact is closed
If desired, both circuits can be made to latch by operating with dc instead of the indicated ac supply. In both of these circuits, voltage across the sensitive contacts is under 5 volts, and contact current is below 5 mA.
For inductive loads, Rl would normally be returned to the opposite side of the load as shown in C.
This article was originally published in a slightly modified form in the QST magazine, December 1998 and January 1999, and in the Radio Amateur's Handbook, 1999. Visit the American Radio Relay League for information on these publications and a world...
The most challenging aspect of the build was to find or design a circuit capable of handling the load while remaining within budget. This circuit achieves both objectives. It adjusts the power output using a potentiometer (variable resistor) R1, which...
The circuit depicted in the figure is designed to achieve a higher power output by modifying specific components. On the left side of the figure, components R1, L1, D1, and capacitors C1 to C7 form a conventional filtering and rectifying...
In this circuit, a full-wave bridge is switched to a full-wave center tap to reduce regulator dissipation. SCR D6 switches between configurations. When D6 is off, the circuit is an FWCT rectifier using D1, D2, and D5. It applies 17...
The switching power supply provides 12 volts at a maximum of 10 amps, utilizing a discrete transistor regulator with an operational amplifier acting as a comparator in the feedback circuit. The schematic does not depict the front panel power-on indicator....
The half-linear design allows for reduced thermal considerations, as the linear regulator only needs to handle 1-5W instead of the full 75W per rail. MOSFETs operate in their linear region, just below the rated voltage for RDS(on), but they are...
This switching circuit functions as a bank of interlocked mechanical switches. Activating one of the buttons latches its corresponding output while unlatching a previously selected output. A pair of inverters creates a latch for each output. For instance, pressing button...
How often does it happen that a user closes down Windows and then forgets to turn off the computer? This circuit addresses that issue by automatically powering off the computer after Windows has been shut down.
This circuit operates by monitoring...
The T amplifier circuit schematic section is illustrated in Figure 3-51. It utilizes the Japan Sanyo STK6303 Pina, which is a high-power thick film integrated circuit. The maximum power supply voltage is 36V, and the output current can reach approximately...