Description: The RTD temperature data collected at the scene is converted into a voltage using the XTR112/114. This voltage is further transformed into a 4 to 20 mA current output, which is then transmitted via a twisted pair. The RCV420 receives the signal, and an ISO124 isolation amplifier is utilized to provide an output of 0 to 5V. The circuit exhibits excellent anti-jamming performance, making it suitable for long-distance transmission in environments with significant interference. The schematic illustrates a three-wire RTD connection; if a two-wire RTD is used, RLIN2 should be removed.
The circuit design begins with the RTD (Resistance Temperature Detector), which is a temperature sensor that provides a resistance change proportional to temperature. The XTR112/114 is an integrated circuit specifically designed for converting the resistance change from the RTD into a corresponding voltage signal. This voltage is then converted into a standard 4 to 20 mA current loop output, which is a common industrial standard for signal transmission, allowing for long-distance signal integrity.
The twisted pair wiring used for transmission minimizes electromagnetic interference, which is crucial in industrial environments. Upon reaching the receiving end, the RCV420 module is employed to capture the 4 to 20 mA signal, ensuring that the signal is accurately interpreted. The ISO124 isolation amplifier serves to electrically isolate the output from the input, providing protection against surges and noise, and converting the current signal into a 0 to 5V voltage output suitable for further processing or display.
The circuit's design incorporates robust anti-jamming features, making it ideal for use in environments with substantial electrical noise, such as factories or near heavy machinery. The inclusion of a three-wire RTD configuration in the schematic allows for improved accuracy by compensating for lead resistance. In cases where a two-wire RTD is implemented, the design stipulates the removal of the RLIN2 resistor to maintain proper functionality and accuracy. This adaptability enhances the circuit's versatility in various applications, ensuring reliable temperature measurement and monitoring. As shown, collected at the scene RTD temperature, it is converted into a voltage by the XTR112/114 voltage is converted into 4 ~ 20mA current output, and then the twisted pair transmission, RCV420 reception, isolation amplifier ISO124 isolation amplifier, the output 0 ~ 5V voltage. Excellent anti-jamming performance of the circuit can be applied to long-distance transmission interference or big occasions.
The figure for the three-wire RTD connection, if the connection with the two-wire RTD, then remove RLIN2.
The LM135/235/335 temperature sensor is designed for ease of absolute temperature reading, providing all positive values for any frequency. This is why a voltage of 2.7315V is observed at 0 degrees.
The LM135/235/335 series of temperature sensors are precision devices that...
This design is for a thermometer circuit that utilizes the LM35 integrated circuit (IC) as a temperature sensor. It is a straightforward circuit that allows for the measurement of room temperature using a digital voltmeter or any voltmeter capable of...
More:
The input data contains a brief description section followed by an empty "More" section. There is no additional information provided to elaborate on.
In the context of electronic schematics, a description typically outlines the purpose and functionality of the circuit....
Adjust RP1 and RP2 to set the preset temperature control point. The 555 circuit is configured as a Schmitt inverter circuit that automatically controls a relay device. This forms part of the T-121 temperature control circuit, which includes a temperature...
This DIY digital thermometer circuit can measure temperatures up to 150°C with an accuracy of ±1°C. The temperature is displayed on a 1V full scale deflection.
The digital thermometer circuit is designed to provide accurate temperature readings within a specified range,...
Al's positive input is biased by the thermocouple. Al's output drives a basic voltage-to-frequency (V-F) converter, which consists of 74C04 inverters and related components. Each V-F output pulse results in a fixed amount of charge being transferred from a 100...
The LinkSwitch-LP family is designed to replace inefficient line frequency linear transformer-based power supplies with output powers less than 2.5 W in applications such as cell/cordless phones, PDAs, digital cameras, and portable audio players. LinkSwitch-LP may also be used as...
The dispenser (Aucma) temperature detection control circuit is designed to manage the temperature of the dispenser. It consists of two primary components: a heating control circuit and a fresh cabinet control circuit that provides power to an ozone generator. This...
This design circuit is for a temperature sensor that utilizes an LM335 integrated circuit (IC) to convert ambient temperature into an equivalent output voltage. The output voltage of the LM335 increases by approximately 10 mV for every 1 degree Kelvin...
We use cookies to enhance your experience, analyze traffic, and (if you allow) serve personalized ads.