Description: This circuit is designed to maintain the fluid level of a liquid between two predetermined points. It features two operational modes for either filling or emptying the container, which can be achieved by simply reversing the connections of relay K1. The loads in this system can include electric motors or solenoid-operated valves that function using alternating current (AC) power. Liquid level detection is facilitated by two metal probes, one to sense the high level and the other to detect the low level. Additionally, an inversion of the logic for maintaining a filled container can be accomplished by substituting the normally open contact on the gate of transistor Q3 with a normally closed contact.
This fluid level control circuit employs a simple yet effective relay-based system to manage liquid levels. The two metal probes act as sensors, which are placed at the desired high and low fluid levels within the container. When the liquid reaches the high-level probe, it triggers the circuit to stop filling, while the low-level probe initiates the filling process when the liquid drops below this point.
Relay K1 is central to the operation of this circuit. In its standard configuration, it allows for the flow of current to either fill or empty the container based on the state of the probes. When the circuit is in the filling mode, the relay activates the electric motor or solenoid valve to introduce liquid into the container. Conversely, when in the emptying mode, the relay switches the operation to drain the liquid.
The transistor Q3 serves as a control element, and its gate can be manipulated to alter the logic of the system. By replacing the normally open contact with a normally closed contact, the circuit can be configured to maintain a full container, reversing the operational logic to suit specific application needs.
Overall, this circuit provides a versatile solution for liquid level management, allowing for efficient control of fluid dynamics in various industrial and domestic applications.Use this circuit to keep the fluid level of a liquid between two fixed points. Two modes, for filling or emptying are possible by simple reversing the contact connections of Kl. The loads can be either electric motors or solenoid operated valves, operating from ac power. Liquid level detection is accomplished by two metal probes, one measuring the high level and the other the low level An inversion of the logic (keeping the container filled) can be accomplished by replacing the normally open contact on the gate of Q3 with a normally closed contact.
When an individual touches the safety box or other protected metal objects, the sensor circuit generates a pulse to the alarm circuit. The positive edge of this pulse activates the semiconductor and thyristor flash GE, subsequently triggering the camera to...
The circuit utilizes multiple integrated circuits to form an automatic lighting device that is activated by door and window sensors. It includes CD4093 digital integrated circuits, a relay, and a power supply circuit. The system typically remains closed when a...
The OBO V20C functions as a lightning protection module, capable of handling a maximum lightning damage current of 40 kA. It includes a relay (k), a contactor (KM), a fuse (FU), and traffic lights (HL).
The OBO V20C lightning protection module...
This document serves multiple purposes, primarily to document the methods employed by a Scooba robot to detect: a) the presence of an acceptable cleaning solution being delivered to its pump, and b) the excess presence of used solution collected off...
When the liquid level reaches both probes, the alarm is activated. When the water level recedes, the alarm is deactivated.
The described circuit functions as a liquid level monitoring system utilizing two probes to detect the presence of liquid. The system...
This week's plan is to build a device that warns of the potential for a knockdown, which is the process by which an over-canvassed ship is laid over on her beam-ends. The risk of sinking is high during this event,...
AC power is supplied through AC Fuse F1 and Power On/Off switch S1 to a 6.3V filament transformer T1. An additional safety feature, Fuse F2, is included, as a short circuit to the filament transformer may not trigger the main...
This AC Power Monitor continuously monitors the AC power line voltage for both under-voltage conditions and missing cycles. When it detects a total of 5 or 6 consecutive missing half-cycles (50ms, 50/60Hz), it activates a relay and initiates a timer....
This circuit will emit an intermittent beep (or will flash a LED) when the water contained into a recipient has reached the desired level. It should be mounted on top of the recipient (e.g. a plastic tank) by means of...
We use cookies to enhance your experience, analyze traffic, and (if you allow) serve personalized ads.
By clicking Accept All, you agree to our use of cookies.
Learn more