Description: This demo board data sheet explains how to utilize the HV758DB1 to produce a fundamental high voltage pulse waveform for use as an ultrasound transmitting pulser. The HV758 circuit employs a DC coupling method in all level translators, eliminating the need for external coupling capacitors. The VPP and VNN rail voltages can be modified relatively quickly, in contrast to a high voltage capacitor gate-coupled driving pulser. This direct coupling topology of the gate drivers not only reduces the requirement for two high voltage capacitors per channel but also simplifies the PCB layout. The input stage of the HV758 features high-speed level translators capable of functioning with logic signals ranging from 1.2V to 5.0V, optimized for 2.5V to 3.3V. In this demo board, control logic signals are connected through a high-speed ribbon cable connector. The logic-high control signal voltage should match the VCC voltage of the demo board, while the logic-low should be referenced to GND. The output waveforms from the HV758DB1 can be observed directly using an oscilloscope by connecting the probe to test points TX1 to TX4 and GND. A soldering jumper can be used to select whether to connect the on-board equivalent load, which consists of a 330pF, 200V capacitor in parallel with a 2.5kΩ, 1W resistor. Additionally, a coaxial cable may be employed to connect the user's transducer for convenient driving and evaluation of the HV758 transmitter pulser. The HV758 is a monolithic 4-channel, high-speed, high voltage ultrasound transmitter pulser. This integrated, high-performance circuit is housed in a single 8x8mm, 64-Ball FCBGA package. The HV758 can deliver up to ±2.2A source and sink current to a capacitive transducer. It is intended for medical ultrasound imaging and ultrasound non-destructive testing (NDT) applications. Additionally, it can serve as a high voltage driver for other piezoelectric or capacitive MEMS transducers, as well as for automated test equipment (ATE) systems and pulse signal generators. The circuitry of the HV758 comprises controller logic circuits, level translators, gate driving buffers, and a high current and high voltage MOSFET output stage. The output stages of each channel are designed to provide peak output currents exceeding ±2.5A for pulsing when MC0 = 1 and MC1 = 1, with voltage swings of up to ±90V. In mode 1, all output stages reduce the peak current to ±580mA for low-voltage continuous wave (CW) mode operation to conserve power. Two floating 9VDC power supplies, referenced to VPP and VNN, supply the P-type and N-type power FET gate drivers. The upper frequency limit for the pulser waveform is 20MHz, depending on the load capacitance. One HV758 can also function as four damping circuits to generate fast return-to-zero waveforms when paired with another HV758 configured as four pulsing circuits. Furthermore, it includes built-in under-voltage and over-temperature protection functions to ensure reliable operation.
The HV758DB1 demo board serves as an essential platform for evaluating the performance and capabilities of the HV758 high voltage pulse generator. The integration of high-speed level translators allows for compatibility with various logic levels, facilitating seamless interfacing with different control systems. The direct coupling method enhances the overall efficiency of the system by minimizing component count and simplifying the design, which is particularly advantageous in space-constrained applications.
The output capabilities of the HV758 are particularly noteworthy, with the ability to deliver significant peak currents suitable for driving capacitive loads. This feature is critical in ultrasound applications where rapid pulse generation is required to achieve high-resolution imaging. The flexibility of the HV758 in supporting both pulsing and continuous wave modes allows it to be utilized in a wide range of applications beyond ultrasound, including various types of transducer technologies.
The design considerations for PCB layout are also crucial, as the HV758's performance can be influenced by parasitic capacitances and inductances. Careful attention must be paid to the placement of components, routing of traces, and grounding practices to optimize the performance of the circuit. The built-in protection mechanisms further enhance the robustness of the system, ensuring that it can operate reliably under varying conditions.
Overall, the HV758DB1 demo board represents a versatile and high-performance solution for generating high voltage pulse waveforms, making it an invaluable tool for engineers and researchers in the field of ultrasound technology and beyond.This demo board data sheet describes how to use the HV758DB1 to generate the basic high voltage pulse waveform as an ultrasound transmitting pulser. The HV758 circuit uses the DC coupling method in all Level Translators There are no external coupling capacitors needed.
The VPP and VNN rail voltages CAN be changed rather quickly, compared to a high voltage capacitor gate- coupled driving pulser. This direct coupling topology of the Gate drivers not only saves two high voltage capacitors per channel, but also makes the PCB layout easier. The input stage of the HV758 has high-speed level translators that are able to operate with Logic signals of 1.
2V to 5. 0V and are optimized at 2. 5V to 3. 3V. In this demo board, the control Logic signals are connected to a high-speed ribbon cable connector. The control signal logic-high voltage should be the same as the VCC voltage of the demo board, and the logic-low should be referenced to GND. The HV758DB1 output waveforms CAN be displayed using an oscilloscope directly by connecting the scope probe to the test point TX1 to 4 and GND.
The HV758 is a monolithic 4-channel, high-speed, high voltage, ultrasound transmitter pulser. This integrated, high performance circuit is in a single, 8x8mm, 64-Ball FCBGA package. The HV758 CAN deliver up to a ±2. 2A source and sink current to a capacitive transducer. It is designed for medical ultrasound imaging and ultrasound material NDT applications. It CAN also be used as a high voltage driver for other piezoelectric or capacitive MEMS transducers, or for ATE systems and pulse signal generators as a signal source. HV758 ½ ½s circuitry consists of controller Logic circuits, level translators, Gate driving Buffers and a high current and high voltage MOSFET output stage.
The output stages of each channel are designed to provide peak output currents over ±2. 5A for pulsing, when MC0 = 1 and MC1 = 1, with up to ±90V swings. When in mode 1, all the output stages drop the peak current to ±580mA for low-voltage CW mode operation to save power. Two‚oating 9VDC power supplies referenced to VPP and VNN supply the P- and N-type power FET Gate drivers.
The upper limit frequency of the pulser waveform is 20MHz depending on the load capacitance. One HV758 CAN also be used as four damping circuits to generate fast return-to-zero waveforms by working with another HV758 as four pulsing circuits. It also has built-in, under-voltage and over-temperature protection functions.
The bat ultrasounds are picked up by the microphone SPKR1 and go through two stages of amplification at Q1 and Q2. Separately, a tunable (R12) single frequency is produced by the LM567 oscillator U1. The LM567 is a tone decoder...
The DC voltage for the generator field winding is supplied by a three-phase thyristor rectifier. In instances of incorrect operation, phase misalignment, or system failure, the rectifier may generate hazardous conditions, leading to over-voltage insulation issues on the DC side...
A step-down transformer T1 reduces the incoming line voltage to approximately 48 Vac, which is then rectified by diode D1. The resulting direct current charges capacitor C1 through a current-limiting resistor R1 to a voltage level set by R4. When...
This circuit is designed to demonstrate high frequency and high voltage, capable of producing approximately 30kV, depending on the transformer utilized. It is cost-effective and straightforward to construct, primarily using a standard TV flyback transformer. This circuit can power lasers,...
The bat ultrasounds are picked up by the microphone SPKR1 and go through two stages of amplification at Q1 and Q2. Separately, a tunable (R12) single frequency is produced by the LM567 oscillator U1. The LM567 is a tone decoder...
A high voltage power supply is a valuable source that can be effectively used in various applications, such as biasing gas-discharge tubes and radiation detectors. This type of power supply can also serve as a protective measure, such as electrically...
This is a series regulator with Q900 being the control element, Q901 a driver, and Q902 an error amp. ZD900 forms the emitter reference voltage source. Since the generated high voltage and other voltages are linked by means of the...
This inverter circuit operates using a transistor and transformer, along with other components, to elevate the voltage. The input supply voltage ranges from 3V to 6V DC, which is then converted to a high voltage AC output. However, the output...
The goal is to create two circuits: one transmitter and one receiver for ultrasound applications. A pair of 25 kHz transmitter and receiver units is already available.
To design an ultrasound transmitter and receiver circuit operating at 25 kHz, the following...