PS10 Quad Power Sequencing Controller - Supertex Inc
Description: The PS10 saves board space, improves accuracy, eliminates optocouplers or level shifts, and reduces overall component count by combining four programmable timers, input under-voltage (UV) and over-voltage (OV) supervisors, a programmable power-on reset (POR), and four 90V open drain outputs. A high reliability, high voltage, junction isolated process allows the PS10 to be connected directly across the high voltage input rails. By Supertex, Inc.
The PS10 integrated circuit is designed to optimize circuit design by consolidating multiple functionalities into a single component. This device combines four programmable timers and supervisors for under-voltage and over-voltage monitoring, which enhances the accuracy of voltage regulation and system stability. The programmable power-on reset (POR) feature ensures that the system initializes correctly after power is applied, preventing erratic behavior during startup.
The inclusion of four open drain outputs rated for 90V provides flexibility in interfacing with various high-voltage systems while maintaining a low component count. This configuration is particularly advantageous in applications where space is at a premium, as it reduces the need for additional discrete components such as optocouplers or level shifters.
The high reliability of the PS10 is achieved through a junction isolated process, which allows for direct connection to high voltage input rails without the risk of cross-talk or interference between the different functions of the device. This isolation is critical in high-voltage applications where safety and performance are paramount.
Overall, the PS10 represents a significant advancement in integrated circuit design, offering a compact solution for complex timing and voltage supervision tasks in high-voltage environments. Its features facilitate more efficient circuit layouts and contribute to the overall reliability and performance of electronic systems.The PS10 saves board space, improves accuracy, eliminates Optocouplers or level shifts and reduces overall component count by combining four Timers programmable input UV/ OV supervisors, a programmable POR, and four 90V open drain outputs. A high reliability, high voltage, junction isolated process allows the PS10 to be connected directly across t
The input voltage for the high-voltage DC-DC converter is 12V AC at 800mA, which is then converted to DC using a 1A bridge rectifier diode. The output voltage of the converter can be adjusted within the range of 0-1000V DC....
Working Principle: The circuit, as illustrated in figure 4-187, is composed of three main components: the power circuit, the pulse oscillator, and the high voltage generator. The power circuit includes components S, FU, TI, VD1-VD4, C1, C3, IC1, R1, and...
A high voltage power supply DC converter that operates between 3V to 500V has been suggested for use with Geiger tubes. However, during simulation, the output remained at nearly 9V, which matches the input voltage. The schematic drawn has only...
This circuit is designed to demonstrate high frequency and high voltage, capable of producing approximately 30kV, depending on the transformer utilized. It is cost-effective and straightforward to construct, primarily using a standard TV flyback transformer. This circuit can power lasers,...
This figure illustrates a method for generating a momentary 10-kV voltage pulse to initiate plasma discharge across a laser tube. A diode voltage-multiplier circuit is connected in series with the main supply, obtaining its input power from one of the...
The output voltage varies approximately linearly up to 20 kV as the input voltage is adjusted from 0 to 5 V. A 5-0 potentiometer is used to tune the oscillator, optimizing the output voltage at the frequency of maximum transformer...
Energy storage capacitors in even the smallest disposable camera flash powered by a 1.5 V AA battery can be hazardous under certain conditions. Line-powered devices, regardless of size, may present additional risks due to high power at high voltage and...
By utilizing an RC oscillator and a programmable divider, this counter can operate for extended periods. The interval oscillator functions at a frequency determined by specific component values: for instance, with R1 = 390 kΩ and C2 = 10 µF,...
This circuit is a high voltage regulator that features foldback current limiter protection. It utilizes the LM10 comparator along with a voltage reference in its core design.
The high voltage regulator circuit is designed to maintain a stable output voltage while...
We use cookies to enhance your experience, analyze traffic, and (if you allow) serve personalized ads.
By clicking Accept All, you agree to our use of cookies.