Description: When using a regulated power supply to lower a supply voltage, there is always a risk that a failure in the power supply could result in a significant overvoltage condition across the load. To address overvoltage situations, the circuit is designed to protect the load during such conditions. The component values provided are for a 20 V supply with a regulated output of 12 V. The zener diode can be replaced with one that corresponds to the desired maximum voltage.
If the voltage at the regulator output exceeds 13 V, the zener diode enters breakdown mode and activates the thyristor, which then shorts the supply line and causes the main fuse to blow.
The described circuit provides a robust solution for overvoltage protection in regulated power supply systems. The primary components include a voltage regulator, a zener diode, a thyristor, and a fuse. The voltage regulator is responsible for maintaining a stable output voltage, while the zener diode serves as a voltage reference. When the output voltage approaches the predefined threshold of 13 V, the zener diode will conduct in reverse breakdown, allowing current to flow through it.
This current triggers the thyristor, a semiconductor device that can conduct current in one direction when it is activated. Once the thyristor is turned on, it creates a low-resistance path to ground, effectively shorting the power supply output. This action diverts the excess voltage away from the load, preventing damage to sensitive components. The main fuse in the circuit is designed to protect the entire system by breaking the circuit if the current exceeds a safe level, thus ensuring that no further damage occurs.
The choice of the zener diode is critical; it should be rated for the maximum voltage that the circuit is intended to handle. Adjusting the zener diode value allows for customization of the overvoltage threshold, making the circuit adaptable to various applications. The overall design emphasizes reliability and safety, ensuring that the load remains protected even in the event of a fault in the power supply.When using a regulated power supply to reduce a supply voltage, there is always the danger that component failure in the power supply might lead to a severe overvoltage condition across the load. To cope with overvoltage situations, the circuit is designed to protect the load under overyoltage conditions.
Component values given are for a 20 V supply with regulated output at 12 V. The zener diode can be changed according to whatever voltage is to be the maximum If the voltage at the regulator output rises to 13 V or above, the zener diode breaks down and triggers the thyristor which shorts out the supply line and blows the main fuse.
The Chameleon II Power Supply Circuits convert the raw input supply into stable voltage outputs necessary for the Chameleon interfaces. The outputs provided are +5V, +12V, and -12V.
The Chameleon II Power Supply Circuits are designed to ensure reliable operation of...
A 5.1-V zener diode is utilized to clamp positive-going transients, while a Schottky rectifier is employed to clamp negative-going transients. The Schottky rectifier, however, experiences issues at both extremes of the temperature range. At 125°C (257°F), its leakage current can...
This circuit utilizes a 13-volt zener diode, D2, which is responsible for voltage regulation. Approximately 0.7 volts are dropped across the base-emitter junction of the transistors, resulting in a higher current output of 12.3 volts. The circuit is capable of...
To protect downstream circuits from overvoltage conditions that occur during load-dump events or transients, the MAX6495, MAX6499, MAX6397, and MAX6398 can be utilized.
The MAX6495, MAX6499, MAX6397, and MAX6398 are integrated circuits designed for overvoltage protection in various electronic applications. These...
This circuit offers a cost-effective and dependable method for testing zener diodes. The variable resistor RV1 can be calibrated in volts, allowing the user to determine the zener voltage directly by observing when LED 1 begins to illuminate. At this...
This circuit generates three source-regulated voltages using a minimal number of electronic components. The output DC voltages are +12V, +5V, and -5V. Diodes D2 and D3 perform full-wave rectification while charging capacitor C2 during each half of the alternating current...
Here is a handy zener diode tester which tests zener diodes with breakdown voltages extending up to 120 volts. The main advantage of this circuit is that it works with a voltage as low as 6V DC and consumes less...
This circuit protects expensive portable equipment against all types of improper hookups and environmental hazards that could cause an overvoltage condition. It operates very quickly and does not latch up; rather, it recovers when the overvoltage condition is removed. In...
The circuit utilizes a Zener diode (D1) for overvoltage protection and a diode rectifier bridge for reverse voltage protection. The 1.4V drop across the diodes will result in a maximum voltage loss, meaning that the supply voltage (VPS) must be...