Description: This circuit utilizes a relay to control a water pump for automatic level regulation of a water reservoir or well. The shorter steel rod acts as a high water sensor, while the longer rod serves as a low water sensor. When the water level is below both sensors, the output of IC1C (pin #10) remains low. As the water level rises and makes contact with the longer sensor, the output stays low until the shorter sensor is activated. At this point, the output of IC1C transitions to high, causing Q1 to conduct, energizing the relay, and initiating the pump operation. As water is pumped out, the level decreases, and the shorter sensor is no longer submerged; however, the output of IC1C remains high due to feedback from pin #5 of IC1B, allowing the pump to continue operating. When the water level drops below the longer sensor, the output of IC1C returns to low, stopping the pump. An optional switch, SW1, can be added to enable reverse operation. When SW1 is activated to connect R3 to pin #11 of IC1D, the pump will operate when the reservoir is nearly empty and cease operation when the reservoir is full, effectively allowing the pump to fill the reservoir instead of emptying it, as is the default mode of operation.
The circuit design employs a relay to control the operation of a water pump based on the water level detected by two sensors. The shorter sensor, positioned at the high water mark, and the longer sensor, at the low water mark, provide critical feedback to the integrated circuit (IC1C). The logic within IC1C determines the state of the pump based on the water level detected by these sensors.
Initially, when the water level is low, both sensors do not make contact with the water, resulting in a low output from IC1C. As water fills the reservoir, it first contacts the longer sensor, but the output remains low until the shorter sensor is activated. The transition of IC1C to a high output triggers Q1, which energizes the relay, activating the pump. This action begins to lower the water level in the reservoir.
While the pump operates, the water level will eventually drop below the shorter sensor, but the output of IC1C remains high due to the feedback from IC1B, allowing the pump to continue functioning until the water level reaches the longer sensor. At this point, the output of IC1C returns to low, signaling the pump to stop.
The inclusion of an optional switch, SW1, allows for versatility in operation. By connecting R3 to pin #11 of IC1D, the circuit can be reconfigured such that the pump operates in reverse. In this mode, the pump will start when the water level is low and stop when the reservoir is full, allowing for the filling of the reservoir instead of its emptying.
This configuration provides a reliable solution for automatic water level management, ensuring efficient operation of the pump while also allowing for flexibility in its intended use. The use of feedback mechanisms within the integrated circuits ensures that the system reacts appropriately to changes in water level, maintaining the desired operational parameters.By means of a Relay, employed to drive a water pump, this circuit provides automatic level control of a water reservoir or well. The shorter steel rod is the water high sensor, whereas the longer is the water low sensor. When the water level is below both sensors, IC1C output (pin #10) is low; if the water becomes in contact with the longer
sensor the output remains low until the shorter sensor is reached. At this point IC1C output goes high, Q1 conducts, the Relay is energized and the pump starts operating. Now, the water level begins to decrease and the shorter sensor will be no longer in contact with the water, but IC1C output will be hold high by the signal return to pin #5 of IC1B, so the pump will continue its operation.
But when the water level falls below the longer sensor, IC1C output goes low and the pump will stop. SW1 is optional and was added to provide reverse operation. Switching SW1 in order to connect R3 to pin #11 of IC1D, the pump will operate when the reservoir is nearly empty and will stop when the reservoir is full. In this case, the pump will be used to fill the reservoir and not to empty it as in the default operating mode.
The circuit illustrated in Figure 3-56 features both manual and automatic start-up modes. It incorporates two relays, KA2 and KA3, within the control loop. The circuit design ensures that KM1 is cut off before and after activating KM2. A main...
A monostable relay has two states: operative when a sufficient current flows through its coil and quiescent when no current flows. A relay contact that assumes a certain position after the supply voltage has been switched on is required in...
The schematic below illustrates 4 methods of controlling a relay with a digital logic signal. Figure (A) can probably be used in most cases where the relay coil requires 100 mA or less and the input current is 2 milliamps...
Some relays will become warm if they remain energized for some time. The circuit shown here will actuate the relay as before but then reduce the hold current.
The described circuit addresses the issue of heat generation in relays due to...
The circuit depicted in Figure 6-24 includes a relay coil with both ends connected in parallel to a resistor (Rf) or an auxiliary diode (VD). This configuration is intended to enhance power after a short circuit occurs in the coil...
An NPN bipolar transistor is typically utilized for relay switching, particularly with 12V coil-rated relays, as it helps maintain circuit separation. A diode is also added to prevent issues. The necessity of driving the relay with a transistor depends on...
One of the serious problems in relay-operated circuits is the relay clicking or chattering during the on/off operation of the relay driver transistor. This issue can lead to unreliable circuit performance and may cause premature wear of the relay contacts.
In...
The circuit requires a double pole, double throw relay in conjunction with a single transistor to allow toggling the relay with a momentary push button. One set of relay contacts is used to control the load, while the other is...
This circuit allows a 12v relay to operate on a 6v or 9v supply. Most 12v relays need about 12v to "pull-in" but will "hold" on about 6v. The 220u charges via the 2k2 and bottom diode. When an input...
We use cookies to enhance your experience, analyze traffic, and (if you allow) serve personalized ads.