Description: When using an analog meter to set the output of a power supply for testing 12-volt equipment, an expanded voltmeter scale offers significant advantages in accuracy compared to a linear scale. Figure 1 illustrates the original meter scale alongside the expanded scale used in this scenario. Eref is established as a 5-volt reference voltage through two LM236 reference diodes. The resistors R2 and R4 should retain the same values as in the linear region. Setting R1 to 10K achieves a 1-volt output for a 1-volt input relationship in the expanded region. It is necessary to calculate R3 at the inflection point when Ein equals 10 and Eout equals -1. Here, R1 is the parallel combination of R1A and R1B. For enhanced accuracy, the resistance of the JFETs, approximately 150 ohms, should be factored into the calculations for R3 and R1B. One of the LM1458 operational amplifiers (IC1A) functions as a comparator to drive the gates of the JFETs (Q1, Q2), which switches the configuration of the other operational amplifier (IC1B) between inverting and differential modes. The comparator's switching point corresponds to the inflection point on the operating curve, indicating where the meter transitions from a linear scale to an expanded scale. To accommodate different ranges, the resistor divider formed by R5 and R6 determines the comparator's switching threshold. If the intention is to initiate the expanded portion below 5 volts, a single LM236 can be employed to provide a 2.5-volt reference voltage. For other ranges, the resistor values will need recalculation based on the aforementioned equations. It is important to note that at the inflection point, Ein and Eout must be equivalent for both equations (I) and (III).
The circuit described utilizes an analog meter for measuring voltage outputs from a power supply configured for 12-volt equipment testing. The expanded voltmeter scale is crucial for enhancing measurement accuracy, particularly in applications where precise voltage readings are necessary. The reference voltage, Eref, is generated using two LM236 diodes, which provide stability and precision in the voltage reference.
The resistors R2 and R4 are maintained at their linear region values to ensure consistency in the circuit's performance. The selection of R1 at 10K is pivotal, as it establishes a direct relationship between input and output voltages in the expanded region, allowing for precise calibration of the analog meter.
Calculating the value of R3 at the inflection point, where Ein is 10 volts and Eout is -1 volt, is essential for optimizing the circuit's performance. The parallel configuration of R1A and R1B ensures that the effective resistance matches the design requirements. The inclusion of JFET resistance in the calculations enhances the overall accuracy of the output readings.
The operational amplifier IC1A serves as a comparator, crucial for determining the switching behavior of the JFETs (Q1 and Q2). This switching action is what enables the transition between the linear and expanded scales on the analog meter. The configuration of the second operational amplifier, IC1B, is dynamically altered based on the comparator's output, allowing for flexibility in measurement modes.
Resistors R5 and R6 form a voltage divider that sets the threshold for the comparator's switching point, allowing for adaptability in the measurement ranges. If a lower starting point for the expanded scale is desired, a single LM236 can be employed to provide a 2.5-volt reference, necessitating recalibration of the resistors for different ranges.
Overall, this circuit design exemplifies a sophisticated approach to voltage measurement, balancing precision with adaptability, making it suitable for a variety of testing scenarios in electronic applications.When using an analog meter to set the output of a power supply used for testing 12-volt equipment, an expanded voltmeter scale has a decided advantage and accuracy over a linear scale. Figure 1 shows the original meter scale and the expanded scale used in this example. Eref is a 5-volt reference voltage set by the two LM236 reference diodes. Keep R2 and R4 the same values as in the linear region. Setting R1 = 10K gives a 1 volt output for a 1 volt input relationship in the expanded region. Calculate for R3 when at the inflection point when Ein = 10 and Eout = -1. Note that R1 here is the parallel combination of R1A and R1B. For higher accuracy the resistance of the JFETs of about 150 ohms can be included in the calculations of R3 and R1B. One of the LM1458 op amps (IC1A) is used as a comparator to drive the gates of the JFETs (Q1, Q2) which switches the other op amp`s (IC1B) configuration between the inverting and the differential amplifier.
The point where the comparator switches is the inflection point on the operating curve, i. e. where the meter changes from a linear scale to the expanded scale. To set up for different ranges, the R5 and R6 divider determines where the comparator switches. If desired to start the expanded portion below 5 volts, a single LM236 can be used providing a 2. 5 volt reference voltage. For other ranges the resistors will have to be recalculated from the above equations. Note that at the inflection point Ein and Eout must be the same for both equations (I) and (III).
The MDRC committee approached the author to take on the role of Electronic Components and Project Officer, which was accepted without hesitation. Upon assuming the position, it became evident that more time would be required than initially anticipated, primarily for...
This circuit is a digital voltmeter diagram featuring an LED display. It is designed for measuring the output voltage of a DC power supply. The voltmeter incorporates a 3.5-digit LED display along with a negative voltage indicator. It is capable...
This circuit is a series-FET Voltmeter known as FETVM. The FETVM is designed to replace the function of a vacuum tube voltmeter (VTVM) while simultaneously providing a means to clean the appliance cord. Additionally, the drift rate of this circuit...
This document presents a power-saving voltage regulator circuit. In addition to its general function as a delay regulator, the circuit features: (1) an automatic voltage regulation capability for mains voltage within a range of 220V ±10%, allowing direct power supply...
The supply receives -20 V from the rectifier/filter which is fed to the collector of the Darlington pnp pass transistor, a TIP105. The base drive to the TIP105 is supplied through resistor R5. The base of the TIP is driven...
This is a low-power voltmeter circuit suitable for alternative energy systems operating on 12-volt and 24-volt batteries. The voltmeter features an expanded scale design, allowing it to display small voltage increments within the 10 to 16-volt range for 12-volt batteries...
The circuit was designed to create a high-impedance voltmeter capable of measuring Direct Current (DC) voltages across various types of circuits.
The high-impedance voltmeter circuit typically employs operational amplifiers (op-amps) configured in a non-inverting arrangement to ensure minimal loading on the...
The circuit is designed to be powered directly by a power supply, which is why it does not include a transformer, rectifier, or filter capacitors in the schematic. However, the addition of these components is possible. To operate the circuit,...
Short circuits or broken PCB tracks can be easily identified using a multimeter. However, this tool may yield inaccurate results when assessing the efficiency of a transistor or diode unless the component is unsoldered and removed from the PCB. Additionally,...