Description: This gauge utilizes an Intersil ICL 7106 A/D converter chip along with an LED display module. It incorporates a Sensym Corp. pressure transducer SX100pn (100 psi full scale) arranged in a Wheatstone bridge configuration, which drives an operational amplifier (IC1A, B, C) translator circuit. This circuit outputs a DC voltage to IC2 that is proportional to the pressure measured. Resistor R6 determines the gain of IC1A, establishing the full-scale sensitivity, while R16 is used for zero adjustment. Additionally, IC3 provides regulated +5 V to power the circuit.
The circuit design centers around the Intersil ICL 7106, a precision analog-to-digital converter (ADC) specifically suited for applications requiring high accuracy and low noise. The LED display module connected to the ICL 7106 serves to visually represent the pressure readings in a user-friendly format. The Sensym SX100pn pressure transducer operates within a Wheatstone bridge configuration, which is essential for converting the mechanical pressure into an electrical signal. This configuration enhances sensitivity and accuracy by balancing the bridge, allowing for precise measurement of small changes in resistance caused by pressure variations.
The operational amplifier circuit (IC1A, B, C) is critical in translating the small voltage changes from the pressure transducer into a usable DC voltage signal. The gain set by resistor R6 ensures that the output voltage reflects the full-scale sensitivity of the transducer, thereby allowing the system to accurately measure and display pressure up to 100 psi. The zero adjustment provided by R16 is vital for calibrating the system, ensuring that the output accurately reflects zero pressure when no pressure is applied.
Powering the entire circuit, IC3 regulates a +5 V supply, which is necessary for the proper functioning of the ICL 7106 and the operational amplifiers. This regulated voltage ensures stable operation and consistent performance of the gauge across its operational range. Overall, this design effectively combines precision measurement with user-friendly display capabilities, making it suitable for various applications in pressure monitoring and control systems. Using an intersil ICL 7106 A/D converter chip and an LED display module, this gauge uses a Sensym Corp. pressure tra nsducer SXlOOpn (100 psi full scale) in a Wheatstone bridge configuration to drive an op amp (ICla, b, c) translator circuit that supplies a dc voltage to IC2 that is proportional to pressure. R6 sets the gain of IC1A (full-scale sensitivity) and R16 supplies a zero adjustment. IC3 provides regulated + 5 V to power the circuit.
The analog to digital converter (ADC) is commonly required in most of the projects. Analog voltage measurement can be done using the ADC hardware built in together in a PIC. The picture below shows a simple setup for measuring the...
This verified project provides an idea, circuit, and operation of the LED display temperature indicator. It features a digital temperature indicator utilizing a voltage-to-frequency (V/F) converter, along with various electronic projects.
The LED display temperature indicator is designed to provide a...
The converter has a 60 ms conversion time, consuming 460 pA of current from a 5 V power supply, while maintaining an accuracy of 10 bits at 15 °C within a temperature range of 35 °C. A pulse applied to...
The mechanical chassis prototype, as illustrated in the accompanying image, was constructed using two materials: foam and aluminum. Foam was selected for its ease of manipulation, while aluminum was chosen for its excellent strength-to-weight ratio. The prototype features a rotary...
Today's electronic designs focus on optimizing efficiency to minimize unnecessary power dissipation, aiming to maximize battery life in portable applications and ensure that devices operate as cool as possible. One of the challenges facing designers of synchronous buck PWM controllers...
An IBM PC can operate two 12-bit A/D converters via its printer port. The converters' serial outputs utilize only two of the printer port's eight data lines (DATA A OUT, DATA B OUT). The IBM PC's printer port does not...
This circuit illustrates an ICL7106 interfaced with a silicon transistor to create a digital thermometer. Direct connections between the ICL7106 and an LCD display are depicted in Figure 12-11B. A diode-connected silicon transistor exhibits a temperature coefficient of approximately -2...
The general-purpose circuit of the simple pressure sensor alarm is constructed using a few easily accessible and inexpensive components. The operation of this circuit is straightforward.
The simple pressure sensor alarm circuit typically includes a pressure sensor, an operational amplifier (op-amp),...
An A/D converter by National Semiconductor (ADC0838) converts 0 to 5 V analog inputs into a digital data format. A 9 V battery is utilized. The converter connects to the pointer port connector through a 25-pin connector.
The ADC0838 is a...