Description: The AD170 basic electrical parameters include a temperature coefficient of 25 ppm/°C and a temperature measurement accuracy of ±1°C, with a maximum temperature range of -200°C to +100°C. The power supply required is +5V or -5V, and the operating temperature range is from -40°C to +125°C. The PRTD platinum resistance temperature measurement circuit is utilized. The ADT70 integrates a voltage source, a current source, and an amplifier, resulting in a simple external circuit for temperature measurement, as illustrated in Figure 1-47, which depicts the ADT70 platinum RTD temperature measurement circuit. The PRTD employs a 4-wire configuration, where two wires connect to +IN and A/OUTB, while the other two are grounded and connect to the op-amp. The platinum resistance thermometer, denoted as R, serves as the reference resistor, matching the output current of the current source. OUTA and OUTB are used for reference resistance testing, and the instrumentation amplifier, designated as UNIA, processes the output signal from the platinum resistance thermometer. The op-amp and instrumentation amplifier amplify the output signal, with the gain of the instrumentation amplifier determined by the variable external resistor Rc, following the formula G = 49.9 kΩ / Rc.
The AD170 is a precision temperature measurement device that is particularly well-suited for applications requiring high accuracy and stability over a wide temperature range. The integration of a voltage source, current source, and amplifier within the ADT70 simplifies the design of the temperature measurement circuit, minimizing the need for additional external components. This integration allows for a more compact and efficient design, reducing potential points of failure and enhancing reliability.
In the described PRTD configuration, the 4-wire setup is crucial for eliminating errors due to lead resistance, which can significantly affect measurement accuracy in lower resistance sensors. By using two wires for the measurement and two for the current supply, the circuit can effectively cancel out the resistance of the lead wires, ensuring that the measurement reflects only the resistance of the platinum sensor itself.
The reference resistor R is carefully selected to match the output current of the current source, ensuring that the system operates within its specified parameters. The outputs OUTA and OUTB are connected to the instrumentation amplifier, which is designed to amplify small differential signals. The instrumentation amplifier's high input impedance prevents loading of the sensor and allows for accurate signal processing.
The gain of the instrumentation amplifier is adjustable via the external resistor Rc, providing flexibility in the circuit design to accommodate various measurement ranges and sensitivities. This feature is particularly advantageous in applications where different temperature ranges may need to be monitored without redesigning the entire circuit.
Overall, the AD170 and its associated circuitry represent a robust solution for precision temperature measurement, combining ease of use with high performance, making it suitable for a variety of industrial and laboratory applications.AD170 basic electrical parameters are as follows: temperature coefficient of 25ppm/C, temperature measurement accuracy of l, the maximum temperature in the range of a 200 ~ + I OOOqC, the power supply + 5v or t5v, operating temperature range of -40- + 125 C. ( 1) PRTD platinum resistance temperature measurement circuit. Since ADT70 internal integration of the voltage source, a current source and amplifier, because this use it as a measuring temperature, the external circuit is very simple, as shown in Figure 1-47 is ADT70 platinum RTD temperature measurement circuit. PRTD 4-wire (2-wire one end respectively connected to + INIA,/OUTB, 2 lines are grounded and the other end of the op amplifier of ?
feet) platinum resistance thermometer, R is the reference resistor, matching current source output current, OUTA,/OUTB are applied to the reference resistance test, instrumentation amplifier - UNIA and platinum resistance, the instrumentation amplifier + on INIA, platinum resistance thermometer output signal simultaneously. after the op amp and instrumentation amplifier amplifies the output pin ? instrument gain of the amplifier by the variable external resistor Rc decision G 49. 9kfl/Rc
This is a four-channel temperature measurement adapter that works without an external power supply. It is suitable for measuring temperature and logging its data with a PC. The circuit diagram is very simple and no adjustment is required; everybody will...
The DVM-to-temperature adapter is constructed around a single integrated circuit (IC), the National LM10. This micropower IC features a stable 0.2 V reference, a reference amplifier, and a general-purpose operational amplifier. The circuit is designed to operate within a linear...
This circuit enables the inversion of a reference signal with an accuracy of 1 ppm. It features high input impedance and does not require any trimming.
The described circuit is designed to invert a reference voltage signal while maintaining a high...
This is an application circuit for calibration known as a high voltage AC calibrator circuit. A key aspect of sine wave oscillator design is the stable control of amplitude. In this circuit, the amplitude is stabilized through servo control, which...
This circuit is intended for precision centigrade temperature measurement, with a transmitter section converting to frequency the sensor's output voltage, which is proportional to the measured temperature. The output frequency bursts are conveyed into the mains supply cables. The receiver...
An external power supply that provides a voltage higher than the maximum expected rating of the zener diodes to be tested is required. Potentiometer RV1 is adjusted until the meter reading stabilizes. This reading represents the breakdown voltage of the...
This DIY digital thermometer circuit can measure temperatures up to 150 °C with an accuracy of ±1 °C. The temperature is displayed on a 1V full-scale deflection (FSD) moving-coil voltmeter or digital voltmeter. An operational amplifier IC 741 (IC3) provides...
This circuit requires low noise, stable offset voltages, high open-loop gain, and high speed. These requirements are fulfilled by the HA5147. Standard variations of this circuit can be easily implemented using the HA-5147. For instance, hysteresis can be introduced by...
Industrial applications sometimes require that power be briefly applied to a load following the closure of a switch, such as a microswitch or foot switch. The load could be a heating element used for sealing plastic bags, a DC motor...
We use cookies to enhance your experience, analyze traffic, and (if you allow) serve personalized ads.