Description: This circuit was designed to remotely monitor when a couple of electric heaters have been left on. Its sensor must be placed in contact with the feeder to monitor when the power cable is drawing current, thus causing the circuit to switch on an LED. Any type of high-current load or group of loads can be monitored, such as heaters, motors, washing machines, dishwashers, electric ovens, etc., provided they dissipate a power of at least 0.5 - 1 kW. This design features three versions. The basic one illuminates an LED when the load is on. The second version drives a relay when a pre-set current value flows into the power cable. The third version switches on D7 when the load power is about 1 kW, D6 when the load power is about 2 kW, and D5 when the load power is about 3 kW. The basic circuit is shown at the top left of the drawing and must be used in all three versions. IC1 acts as a differential amplifier with a gain of 220. The small AC voltage picked up by L1 is amplified to a value capable of driving the LED D1. The second version is drawn at the bottom left, must be connected to the basic circuit, and uses a dual op-amp; therefore, IC1 will be labeled IC1A, and its pin connection varies slightly. IC1B acts as a voltage comparator, and its threshold voltage can be precisely set by means of trimmer R6. Q1 is the relay driver, and D2 illuminates when the relay is on. The relay contacts can be used to drive an alarm or a lamp when the AC load exceeds a pre-set value, for example, 2 kW. The third version is shown to the right of the drawing, must be connected to the basic circuit, and uses a quad op-amp; therefore, IC1 will be labeled IC1A, and its pin connection varies slightly. IC1B, C, and D are wired as comparators. They switch on and off the LEDs, referring to voltages at their non-inverting inputs set by the voltage divider resistor chain R11-R14. The sensitivity will be doubled if the inductor is placed tightly between the two wires as shown in the diagram, top left. Conversely, do not place the inductor against paired wires as the signal tends to cancel, and the circuit will not work.
The circuit is designed to provide a versatile solution for monitoring high-current electrical loads. The sensor component, which is critical for the operation, must be strategically placed in contact with the feeder cable to detect current flow effectively. The use of an inductor allows for the detection of alternating current (AC) without direct electrical contact, thus ensuring safety and reliability.
In the basic version of the circuit, the differential amplifier (IC1) amplifies the small AC voltage induced by the current flowing through the feeder line. This amplified signal is sufficient to activate the LED (D1), indicating that power is being drawn by the load.
The second version introduces a relay (Q1) that activates when the current surpasses a predetermined threshold, which is adjustable via the trimmer (R6). This feature allows for the integration of additional devices such as alarms or indicator lamps, enhancing the circuit's functionality. The dual op-amp configuration (IC1A and IC1B) provides the necessary signal processing to ensure accurate current detection and relay activation.
The third version expands the circuit's capabilities further by incorporating multiple comparators (IC1B, C, and D) configured to switch on additional LEDs (D5, D6, D7) based on varying current thresholds (1 kW, 2 kW, and 3 kW). This allows users to visually monitor the power consumption of connected devices, providing a clear indication of load status at different power levels.
Overall, this circuit design is highly adaptable, allowing for the monitoring of a wide range of high-power appliances. Proper placement of the inductor is crucial for optimal performance, as incorrect positioning can lead to signal cancellation, rendering the circuit ineffective. The careful selection of components and configuration ensures reliable operation and accurate monitoring of electrical loads.This circuit was designed on request, to remotely monitor when a couple of electric heaters have been left on. Its sensor must be placed in contact with the feeder to be able to monitor when the power cable is drawing current, thus causing the circuit to switch-on a LED.
Any type of high-current load or group of loads can be monitored, e. g. heater s, motors, washing machines, dish-washers, electric ovens etc. , provided they dissipate a power comprised at least in the 0. 5 - 1KW range. This design features three versions. The basic one illuminates a LED when the load is on. The second version drives a Relay when a pre-set current value flows into the power cable. The third version switches-on D7 when the load power is about 1KW, D6 when the load power is about 2KW and D5 when the load power is about 3KW. The basic circuit is shown top left in the drawing and must be used in all three versions. IC1 acts as a differential amplifier having a gain of 220. The small AC voltage picked-up by L1 is therefore amplified to a value capable of driving the LED D1.
The second version is drawn bottom left, must be connected to the basic circuit and uses a dual op-amp, therefore IC1 will be labeled IC1A and its pin connection varies slightly. IC1B acts as a voltage comparator and its threshold voltage can be precisely set by means of trimmer R6.
Q1 is the Relay driver and D2 illuminates when the Relay is on. You can use the Relay contacts to drive an alarm or a lamp when the AC load exceeds a pre-set value, e. g. 2KW. The third version is shown to the right of the drawing, must be connected to the basic circuit and uses a quad op-amp, therefore IC1 will be labeled IC1A and its pin connection varies slightly.
IC1B, C and D are wired as comparators. They switch on and off the LEDs, referring to voltages at their non-inverting inputs set by the voltage divider resistor chain R11-R14. The sensitivity will be doubled if the inductor is placed tightly between the two wires as shown in the diagram, top left.
On the contrary, do not place the inductor against paired wires as the signal tends to cancel and the circuit will not work.
The circuit of a loop sensor-based simple security alarm is described here. The sensor loop consists of a short length of thin enamelled copper wire.
The loop sensor security alarm operates on the principle of detecting interruptions in the circuit formed...
This circuit was designed on request to remotely monitor when a couple of electric heaters have been left on. Its sensor must be placed in contact with the feeder to be able to monitor when the power cable is drawing...
The change in ambient light triggers the alarm by changing the resistance of LDR1 and LDR2.
The circuit utilizes two light-dependent resistors (LDR1 and LDR2) to detect variations in ambient light levels. LDRs are passive components that exhibit a change in...
A low-cost filament transformer provides a linear indication of the load current in an AC line. This method causes a slight series voltage drop over a wide range of load currents.
A low-cost filament transformer is utilized in applications requiring a...
The resistor (Rl) senses the current flow of a power supply. The JFET is utilized as a buffer since Id equals Is; thus, the output monitor voltage accurately represents the current flow of the power supply.
In this circuit, Rl functions...
The simplest method for measuring high AC currents is to use a clamp meter; however, these devices are typically quite costly, often starting at several hundred dollars. Add-on clamp meter adapters can be effective, but they are compatible only with...
A sensor activates transistor Q1 to turn on the low-frequency 555 oscillator, which generates pulses to control LAMP II. The sensor may respond to variations in light or temperature. Either resistor RA or RB can function as the sensor, depending...
The circuit in Fig. 56-lla activates a signal lamp when it detects a line current consumption exceeding 5 mA and can handle currents of several amperes using suitable diodes in the D1 and D2 positions. Transistor T1 is activated when...
When an individual touches the safety box or other protected metal objects, the sensor circuit generates a pulse to the alarm circuit. The positive edge of this pulse activates the semiconductor and thyristor flash GE, subsequently triggering the camera to...