Description: Rx is placed in the feedback path of IC1. A known reference current is chosen from the reference voltage generator Q1, D1, and resistors R5 through R9. A meter reading will be displayed, where R^ represents Rs through R9, as selected. This is linearly proportional to the value of Rx.
In this electronic circuit, Rx serves as a variable resistor that is strategically positioned within the feedback loop of an operational amplifier, designated as IC1. The feedback configuration allows for precise control and measurement of the output voltage in relation to the input current flowing through Rx. The reference voltage generator, comprising Q1 (a transistor) and D1 (a diode), establishes a stable reference current that is critical for the circuit's operation.
Resistors R5 through R9 are employed to create a series of selectable resistance values, enabling the circuit to adapt to various measurement scenarios. The resistance values are selected through a switching mechanism, which can be either manual or automated, to correspond with the desired measurement range. The total resistance in the feedback loop, denoted as R^, is calculated based on the selected resistor from the series (Rs through R9), ensuring that the circuit can accommodate a range of input signals.
The output of the circuit is connected to a meter, which provides a direct reading of the current flowing through Rx. This output is linearly related to the value of Rx, allowing for straightforward interpretation of the measurement. As Rx changes, the feedback path adjusts the gain of the operational amplifier, thereby affecting the output voltage in a predictable manner. This design is particularly useful in applications requiring precise current measurement and control, such as in sensor interfacing or calibration processes. The linear relationship between the selected resistance and the meter reading allows for easy scaling and interpretation of results, making the circuit versatile for various electronic applications. Rx is inserted in the feedback path of IC1. A known reference current is selected from reference voltage gene rator Ql, Dl, and R5 through R9. A meter reading will be produced: where R^=Rs through R9, as selected. This corresponds linearly to the value of Rx.
This circuit features a linear reading scale, does not require calibration, and does not necessitate zero adjustment. It can be configured for multiple ranges by incorporating different standard resistors.
The circuit operates on the principle of linear response, ensuring that the...
Beige Bag Software has been offering affordable and innovative circuit design tools since 1990. B2 Spice provides schematics as well as analog, digital, and mixed-mode electronic circuit simulation. It integrates with EAGLE and CADSTAR PCB software.
B2 Spice is a powerful...
This program includes circuit design CAD, simulation, and auto-routing PC layout. PSPICE is also utilized at Unisys, which offers more capabilities but costs six times as much and requires annual renewal. With these requirements and others in mind, a variation...
The unknown resistance is connected in series with a known standard resistor, and a current is passed through both components. The voltage developed across the unknown resistor is applied to the input, while the voltage across the known resistor is...
The circuit accurately measures up to 20M when used with a buffer amplifier (Al) that has a low input bias current (IiN) of less than 30 nA. It utilizes two of the three amplifiers found in the Siliconix L144 micropower...
A single preset resistor is utilized across all measurement ranges, which simplifies the setup process. Diode clamping is incorporated to protect the meter from damage if the unknown resistor exceeds the selected range. When the meter is assembled, a 10...
This circuit is designed to provide accurate measurement and a linear resistance scale at the high end. The circuit has four ranges. Additionally, another meter with a current range of 10 µA to 10 mA and a sensitivity of 10,000...
Most analog multimeters are capable of measuring resistance over a wide range of values, but they can be inconvenient to use due to the reverse reading scale, which is also non-linear.
Analog multimeters, often referred to as VOMs (Volt-Ohm-Milliammeter), are versatile...
Most ohmmeters of the design shown in the previous section utilize a battery of relatively low voltage, usually nine volts or less. This is adequate for measuring resistances under several mega-ohms (MΩ), but when extremely high resistances need to be...
We use cookies to enhance your experience, analyze traffic, and (if you allow) serve personalized ads.