Description: Process control applications often require a monostable multivibrator (one-shot) with a pulse width that can be selected on-the-fly. This circuit uses two CD4051B analog multiplexers to select the required timing components for the multivibrator, and hence, the pulse width. The multiplexers' address input comes from an 8-bit latch. Bit D6 tells the multivibrator whether to trigger on the leading or trailing edge of the trigger input. Bit D7 determines whether the multivibrator should be in a retriggerable or non-retriggerable mode.
The described circuit integrates a monostable multivibrator, commonly referred to as a one-shot pulse generator, which is essential in various process control applications where precise timing is crucial. The pulse width of the generated output can be dynamically adjusted, allowing for flexibility in operation. This capability is achieved through the use of two CD4051B analog multiplexers, which are configured to select different timing components based on the application requirements.
The CD4051B multiplexers function as a switch that routes the appropriate timing components to the multivibrator. By utilizing an 8-bit latch, the circuit can manage the address inputs of the multiplexers. The latch holds the binary code that selects which timing components are active, enabling the user to change the pulse width in real-time without needing to redesign or physically alter the circuit.
In this setup, Bit D6 of the latch plays a critical role in determining the triggering mechanism of the multivibrator. It can be configured to respond to either the leading edge or the trailing edge of the trigger input signal. This feature allows for precise control over the timing of the output pulse, making it adaptable to various signal conditions and requirements.
Additionally, Bit D7 of the latch governs the operational mode of the multivibrator. When set to retriggerable mode, the multivibrator can be retriggered by subsequent input pulses, extending the output pulse duration. Conversely, in non-retriggerable mode, the output pulse will only be generated once upon receiving a trigger, regardless of any subsequent triggers during the pulse duration. This dual-mode functionality enhances the versatility of the circuit in different application scenarios.
Overall, the integration of the CD4051B multiplexers and the 8-bit latch in the design of this monostable multivibrator circuit allows for efficient and flexible pulse width modulation, catering to the demanding needs of modern process control systems. Process-control applications often require a monostable multivibrator (one-shot) with a pulse width that c an be selected on-the-fly. This circuit uses two CD4051B analog multiplexers to select the required timing components for the multivibrator, and hence, the pulse width. The multiplexers" address input comes from an 8-bit latch. Bit D6 tells the multivibrator whether to trigger on the leading or trailing edge of the trigger input.
Bit D7 determines whether the multivibrator should be in a retriggerable or nonretriggerable mode.
A wide-range, resistor-programmable monostable multivibrator can be configured for pulse widths ranging from 1 µs to 10 s, providing a 107:1 range. A high-to-low transition at the input causes the output of IC1 to switch low, which turns off transistors...
A monostable multivibrator circuit generates a fixed pulse width when triggered by an input signal. The input is connected to CR1, which should be configured as an open collector source, as TR1 will short the input to ground during the...
This circuit illustrates a precision digital timing control system. The controller includes a crystal oscillator circuit, a divider, a counting circuit, and monostable flip-flops. The crystal oscillator circuit features a series of 14 binary counters/dividers, a watch crystal operating at...
The 322 monostable multivibrator is configured in a cross-connected manner. When operating under non-steady state conditions with the oscillator Unicom, it generates a continuous timing cycle, as illustrated in the accompanying figure. T represents the total time period of three...
This approach utilizes a Hip-Hop, a shift register, and two gates (A). Before the one-shot pulse, the output of the NOR gate is 0. Consequently, the data input of the D-type flip-flop is equivalent to the trigger. When a trigger...
This design is for an interpolating scanner, a circuit featuring multiple signal inputs, a control voltage input, and a signal output. The output selectively transitions between inputs, smoothly fading from one to the next as the control voltage increases. A...
The Dual Timer Exar XR-2556 features a timing mechanism that can be triggered through capacitive coupling on a secondary timing pin. When a trigger input is engaged, the duration T1 can be set to 1.1R1C1, resulting in an increased output...
A monostable multivibrator using the IC CD4538 is a precision device that functions as a monostable/astable multivibrator and is designed to avoid false triggering. This IC is suitable for various applications requiring precise timing cycles. The CD4538 offers improved reliability...
The circuit in Figure 1 converts pulse information to a clean dc voltage by the end of a single incoming pulse. In another technique, an RC filter can convert a PWM signal to an averaged dc voltage, but this method...