Description: The circuit operates as illustrated in Figure 5-2a. It includes an alarm switch (S). When switch S is pressed, relay K is activated, which closes two normally open contacts. This action triggers the alarm bells. The alarm continues to sound even after switch S is released, and it will only stop when the owner turns off the power. Switch S and S6 are functional switches. After pressing S, relay K2 is energized, activating its two normally open contacts, K2A and K2B. Subsequently, pressing S6 energizes relay K4, which causes contacts K4A and K4B to close, allowing power to flow to the electronic lock, thus enabling it to be opened. It is important to note that the sequence of opening switches S8 and S6 cannot be reversed; otherwise, the circuit will become ineffective. Switches S, S7, and S9 are normally closed push-button switches, and only one unlocking switch can be pressed at a time. If the circuit is interrupted, relays K2, K3, and K4 will be re-energized. The schematic is set with a default unlock password of "086," but users can reset the password for the lock if desired.
The described circuit is a security system integrating an alarm mechanism with an electronic locking feature. The primary components include several relays (K, K2, K3, and K4), normally open and normally closed push-button switches (S, S6, S7, S8, and S9), and an electronic lock. The operation begins with the activation of switch S, which triggers relay K. This relay's activation closes its contacts, initiating the alarm system. The alarm remains active until the power is manually cut off, ensuring that any unauthorized access is promptly signaled.
The inclusion of relay K2 allows for the control of additional electrical appliances once switch S is engaged. The relay contacts K2A and K2B are crucial for this function, as they facilitate the flow of electricity to the connected devices. The subsequent action of pressing switch S6 energizes relay K4, which is essential for engaging the electronic lock mechanism. The lock is designed to operate smoothly, thanks to the closure of contacts K4A and K4B, which complete the circuit necessary for unlocking.
It is critical to adhere to the specified sequence of operations for switches S8 and S6, as reversing this order will render the circuit inoperative. The system is designed with safety in mind, utilizing normally closed switches to prevent accidental unlocking. This feature ensures that the circuit remains secure unless a deliberate action is taken to unlock it.
The system also includes a customizable password feature, allowing users to set their own unlock code, enhancing the security of the electronic lock. The default code of "086" serves as a starting point, but users are encouraged to change it to a more secure option to prevent unauthorized access. Overall, this circuit design exemplifies a robust approach to security, combining alarm functionality with electronic locking capabilities in a single schematic.Circuit works: Figure 5 -2a in S. Alarm switch. If you press S, after the relay K. Electrical work, two normally open contacts Pull, so that the alarm bells sound. At this time, even when you release s. Alarm sound is still large, and so only after the arrival of the owner off the power to stop the alarm. so, S. , S6 valid switch. After pressing so, K2 relay energized electrical appliances, two normally open contacts K2A, Kze pull; and finally press S6, K4 relay is to energize, K.
A, K4B normally open contact sticking, thereby turning on the power smoothly electronic lock to open the lock. Note that so, s8, S6 open order can not be reversed, otherwise invalid. S: a S ,, S7, S9 are normally closed push button switch, unlocking switch can not be pressed several, whether the circuit is broken, K2, K3, K4 relay re-energized.
The schematic set unlock password is "086", of course, readers can also reset the password lock.
Safety is a significant concern in many motor-driven applications. This is particularly true in industrial settings where motion begins immediately upon the application of power.
In motor-driven applications, safety mechanisms are essential to prevent accidents and ensure the well-being of operators...
A relay sequencer is utilized in a radio transverter to activate specific stages sequentially after a brief delay. This project outlines the construction of this sequencer, which features a stage that switches the output/input of the driving radio to the...
This circuit design for a low current relay is intended for use in battery-operated electronic devices, with an operating current in microamperes (µA). It utilizes a bistable relay and additional components to enable the relay to function similarly to a...
A reader named Andrea ([email protected]) submitted a circuit designed for educational purposes. The primary objective is to demonstrate how to electronically toggle an output state using only a push-button switch. According to Andrea, this simple circuit can drive a monostable...
This circuit will activate and deactivate a relay with the press of a button. Any momentary push-to-make switch can be utilized. Pressing the button once will activate the relay, while pressing it a second time will deactivate the relay. The...
A relay control circuit is illustrated, which is commonly found in microwave switches. This circuit facilitates the operation of various components such as the power supply switch, electric fans, light bulbs, food turntables, and timers. The relay control signal circuit...
The circuit depicted in Figure 3-162 includes several components: SBi serves as the forward start button, SBz functions as the reverse start button, and SB3 is designated as the stop button. The resistance levels for the start switches are managed...
A single zone alarm circuit with entry and exit delay and other facilities. The circuit features automatic exit and entry delays, timed bell cut-off and system reset. It has provision for normally open and normally closed switches and will suit...
This project originated from the need to control home heating remotely from work. Utilizing a VPN connection between work and home, a relay controlled by a PC was considered the simplest solution. However, a control unit that could be operated...
We use cookies to enhance your experience, analyze traffic, and (if you allow) serve personalized ads.
By clicking Accept All, you agree to our use of cookies.
Learn more